BXSZ 1 / 2 0 LINKAGE SET SERIES FOR AMPOULE CLEANING, STERILIZING, FILLING AND SEALING
Applications:
BXSZ 1 / 2 0 linkage set consists of a QCL series vertical ultrasonic cleaning machine, A SZA series airflow sterilizing &drying machine and a DGF (or DGA) series filling &sealing machine. It can be carry out the ampoule processing procedures such as ultrasonic cleaning machine, sterilizing ,drying, filling, and sealing ,etc. it can be used for the production of 1to 20 ml ampoules.
The processing procedures show as follows:
Water spraying→ ultrasonic washing → external rinse→ first circulating water rinse → second circulating water rinse→ first compressed air blowing → rinse fresh water → second compressed air blowing→ third compression air blowing→ air blowing →preheating→ sterilizing →cooling → bottle in-feed through screw conveyor → pre nitrogen flushing →filling →after nitrogen flushing→preheating →sealing→bottle out-feed and counting.
Specifications:
- Output unit: bottles/hour
NO.
An ultrasonic cleaning machine + sterilizing & drying machine +a filling and sealing machine
1 ml - 2 ml
5 ml
1 0 ml
2 0 ml
1
QCL 6 0 A + SZA 4 2 0 / 2 7 + DGA 6 / 1 - 2 0
1 6 0 0 0
12000
8000
6000
2
QCL 8 0 A + SZA 6 2 0 / 3 8 + DGF 8 / 1 - 2 0 ( DGA 8 / 1 - 2 0 )
2 2 0 0 0
16000
11000
8000
3
QCL 1 0 0 A + SZA 6 2 0 / 3 8 + DGF 1 0 / 1 - 2 0 ( DGA 1 0 / 1 - 1 0 )
28000
20000
1 4 0 0 0
10000
4
QCL 1 2 0 A + SZA 6 2 0 / 3 8 + DGF 1 2 / 1 - 1 0
33000
24000
17000
12000--
2. Qualified clean ampoule rate: ≥ 99%
3. Ampoule breakage rate: ≤ 0.2%
4. LF (Laminar flow) air clarity: 100 grades
5. Sterilizing temperature: 300℃(domestic filter);350℃(imported filter, additional)
6. Qualified filling& sealing rate: 99 %( standard solutions)
7. Counting error: accord with the stipulation of Chinese pharmacopoeia about injection device